<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fire Damper | HVAC Damper Manufacturers &amp; Suppliers | Oman</title>
	<atom:link href="https://airmasteroman.com/product-category/fire-damper/feed/" rel="self" type="application/rss+xml" />
	<link>https://airmasteroman.com/product-category/fire-damper/</link>
	<description>HVAC Products</description>
	<lastBuildDate>Wed, 05 Mar 2025 06:24:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.2</generator>

<image>
	<url>https://airmasteroman.com/wp-content/uploads/2018/06/cropped-mms-logo-32x32.jpg</url>
	<title>Fire Damper | HVAC Damper Manufacturers &amp; Suppliers | Oman</title>
	<link>https://airmasteroman.com/product-category/fire-damper/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Fire Damper</title>
		<link>https://airmasteroman.com/product/fire-damper/</link>
		
		<dc:creator><![CDATA[ammism]]></dc:creator>
		<pubDate>Thu, 25 Feb 2016 21:47:01 +0000</pubDate>
				<guid isPermaLink="false">http://localhost/airmaster1/product/fire-damper/</guid>

					<description><![CDATA[<h4>Construction:</h4>
<p><strong>Frame:</strong> High quality galvanized Iron Sheet of 1.6mm thickness.<br />
<strong>Blades:</strong> Interlocking type blades roll formed from 1mm thick galvanized steel.<br />
<strong>Blade Ramp:</strong> Formed from 1.6mm thick galvanized steel with a spring holder.<br />
<strong>Springs:</strong> 2nos. constant force stainless steel springs.<br />
<strong>Fusible Links:</strong> UL listed fusible links which has fire rating of 165° F / 212° F.</p>
<p>The post <a href="https://airmasteroman.com/product/fire-damper/">Fire Damper</a> appeared first on <a href="https://airmasteroman.com">Airmaster Oman</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="font-family: Verdana,Arial,Helvetica,sans-serif;">Fire damper is a device installed in an air distribution system or an air transfer opening designed to close automatically upon detection of heat interrupting airflow and thereby restricting the passage of fire in the process. Fire dampers are installed in fire rated walls/barriers/partitions (sleeve required) where the HVAC ductwork penetrates ensuring that their integrity is maintained. The location and installation procedure of <a href="http://airmasteroman.com/product/fire-damper">fire damper</a> should be in accordance with the widely accepted and recommended standard, <i>NFPA 90A – Standard for the installation of Air-Conditioning. </i></div>
<p><b>Airmaster </b>fire damper is developed with the intention of maximizing occupant&#8217;s safety.</p>
<div style="font-family: Verdana,Arial,Helvetica,sans-serif;"><strong style="color: #0076ae;">Construction:</strong><br />
<strong>Frame:</strong> High  quality  galvanized  Iron  Sheet  of 1.6mm thickness.<br />
<strong>Blades:</strong> Interlocking type  blades  roll  formed  from  1mm thick galvanized steel.<br />
<strong>Blade  Ramp: </strong>Formed  from  1.6mm  thick  galvanized steel with a spring holder.<br />
<strong>Springs:</strong> 2nos.  constant  force  stainless  steel springs.<br />
<strong>Fusible  Links: </strong>UL  listed  fusible  links  which  has fire rating of 165<span id="main" style="visibility: visible;"><span id="search" style="visibility: visible;">°</span></span>  F /  212<span id="main" style="visibility: visible;"><span id="search" style="visibility: visible;">°</span></span>  F.<br />
<strong style="color: #0076ae;">Description:</strong></p>
<ul>
<li>Fire damper  frame  is  made  from  1.6mm  thk.  high  quality galvanized steel sheet.  All  welded  joints  are  rust proofed by zinc  paint  coating.  The fire damper blades are roll formed from 1mm thk. galvanized steel. The interlocking type blades are designed  with  hat shaped reinforcement ridges ensuring strength and stability.  The  blade  ramp  is  formed  from  1.6mm  thk. galvanized steel with a spring holder. The  ramp  is frmly  secured  to  the  frame  by  rivets.  Constant force  stainless steel  springs  are  firmly secured to the  blades  and  held  in  place  on  the  ramp.  The blades are secured by UL listed fusible links which has  a  fire  rating  of  165<span id="main" style="visibility: visible;"><span id="search" style="visibility: visible;">°</span></span>F  /  212<span id="main" style="visibility: visible;"><span id="search" style="visibility: visible;">°</span></span>F and  thus  kept out of the air-stream when not in operation.</li>
<li>The  heat  responsive  links  on  detection  of  heat beyond  165<span id="main" style="visibility: visible;"><span id="search" style="visibility: visible;">°</span></span>F  /  212<span id="main" style="visibility: visible;"><span id="search" style="visibility: visible;">°</span></span>F  release  the blades  from their position. Upon release, the blades  which are connected  to  the  springs  are  pulled  down  by  the springs  and  get  automatically  locked  on  a  latch and remains so until reset. These fire dampers are 1 rated up to  1/2 hours rating  with  low leakage. All dampers  are  manufactured  in  compliance  to  the UL 555 standards and the company&#8217;s quality control procedures.</li>
<li>Upon the termination of fire condition, the damper can be re-opened (usually an  access door  has to be provided for inspection) by simply pulling up the curtain blades and replacing the fusible link.</li>
</ul>
<p><strong style="color: #0076ae;">Fusible Link:</strong><br />
<strong>Vertical:</strong>   UL Listed 165<span id="main" style="visibility: visible;"><span id="search" style="visibility: visible;">°</span></span>F / 212<span id="main" style="visibility: visible;"><span id="search" style="visibility: visible;">°</span></span>F fusible link as standard.<br />
<img decoding="async" class="alignleft" src="http://airmasteremirates.com/media/Fire Damper1.jpg" alt="" /></p>
</div>
<p><strong>Horizontal: </strong>UL Listed 165<span id="main"><span id="search">°</span></span>F fusible link as standard</p>
<div style="font-family: Verdana,Arial,Helvetica,sans-serif;">
<p><strong><img fetchpriority="high" decoding="async" class="alignleft" src="http://airmasteremirates.com/media/Fire Damper2.jpg" alt="" width="389" height="270" /></strong></p>
<p style="text-align: center;">
</div>
<p>The post <a href="https://airmasteroman.com/product/fire-damper/">Fire Damper</a> appeared first on <a href="https://airmasteroman.com">Airmaster Oman</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Motorized Smoke Damper</title>
		<link>https://airmasteroman.com/product/motorized-smoke-damper/</link>
		
		<dc:creator><![CDATA[ammism]]></dc:creator>
		<pubDate>Thu, 25 Feb 2016 21:47:01 +0000</pubDate>
				<guid isPermaLink="false">http://localhost/airmaster1/product/motorized-smoke-damper/</guid>

					<description><![CDATA[<h4>Construction:</h4>
<p>Frame: High quality galvanized Iron Sheet of 1.6mm thickness.<br />
Blades: Single skin roll formed from high quality steel sheet of thickness 16 gauge.<br />
Actuator: Fast acting , two position Honeywell actuator<br />
Gasket: UL Listed<br />
Jamb Seal: Stainless Steel</p>
<p>The post <a href="https://airmasteroman.com/product/motorized-smoke-damper/">Motorized Smoke Damper</a> appeared first on <a href="https://airmasteroman.com">Airmaster Oman</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="font-family: Verdana,Arial,Helvetica,sans-serif;">
<p style="display: inline !important;"><strong><span style="text-decoration: underline;">Motorized Smoke damper </span></strong></p>
<p><a href="http://airmasteroman.com/product/motorized-smoke-damper">Motorized Smoke damper</a> is a device installed in an air distribution system or an air transfer opening designed to close automatically upon detection of smoke, interrupting the airflow and thereby restricting the passage of fire in the process. The location and installation procedure of fire dampers should be in accordance with the widely accepted and recommended standard, <i>NFPA 90A – Standard for the installation of Air-Conditioning. </i><br />
SMOKE inhalation during fire accidents is one of the major reason for deaths during building fires<b>. Airmaster Motorized Smoke damper </b>is developed with the intention of maximizing occupant&#8217;s safety.<br />
<strong style="color: #0076ae;">Construction:</strong><br />
<strong>Frame:</strong> High  quality  galvanized  Iron  Sheet  of 1.6mm thickness.<br />
<strong>Blades:</strong> Single skin roll formed from high quality steel sheet of thickness 16 gauge.<br />
<strong>Actuator: </strong>Fast acting , two position Honeywell actuator<br />
<strong>Gasket:</strong> UL Listed<br />
<strong>Jamb Seal: </strong>Stainless Steel<br />
<strong style="color: #0076ae;">Description:</strong></p>
</div>
<ul>
<li>Available with Class II leakage, rated at 2000fpm (10.2m/s) / 4”w.g(1000pa).Suitable for most of the commercial smoke management applications in both static and dynamic systems.</li>
<li>All corners of the frame are fully welded (and painted to prevent rust) to make construction more sturdy for a rattle free operation.</li>
<li>Designed for parallel blade operation.</li>
<li>AMSD series is UL 555S classified manufactured under Airmaster’s strict quality control procedures..</li>
<li>Supplied with 230VAC actuators as standard.</li>
<li>Actuators are supplied without auxiliary switch as standard.</li>
<li>Actuator position will be based on Clockwise (CW) closure direction as standard.</li>
<li>Factory fitted with 400mm wide &amp; 1.2mm thick steel sleeve.</li>
<li>All dampers are factory tested to ensure smooth operation before dispatch.</li>
<li>Actuators have to be configured with control panel or BMS system for smoke control applications before commissioning.</li>
</ul>
<p><strong style="color: #0076ae;">Maximum Approved Sizes:</strong></p>
<ul>
<li>Multiple section : 280” x  35” (vertical installation only)   OR   140&#8243; x 70&#8243;  (vertical installation only)</li>
<li>Single section : 35” x  35” (vertical installation only)</li>
</ul>
<p>The post <a href="https://airmasteroman.com/product/motorized-smoke-damper/">Motorized Smoke Damper</a> appeared first on <a href="https://airmasteroman.com">Airmaster Oman</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Motorized Fire Damper</title>
		<link>https://airmasteroman.com/product/motorized-fire-damper/</link>
		
		<dc:creator><![CDATA[ammism]]></dc:creator>
		<pubDate>Thu, 25 Feb 2016 21:47:01 +0000</pubDate>
				<guid isPermaLink="false">http://localhost/airmaster1/product/motorized-fire-damper/</guid>

					<description><![CDATA[<h4>Construction:</h4>
<p>Frame: High quality galvanized Iron Sheet of 1.6mm thickness.<br />
Blades: Single skin roll formed from high quality steel sheet of thickness 16 gauge.<br />
Actuator: Fast acting , two position Honeywell actuator<br />
TRD: Belimo make TRD, 165° F temperature rating.<br />
Jamb Seal: Stainless Steel</p>
<p>The post <a href="https://airmasteroman.com/product/motorized-fire-damper/">Motorized Fire Damper</a> appeared first on <a href="https://airmasteroman.com">Airmaster Oman</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="font-family: Verdana,Arial,Helvetica,sans-serif;">
<p style="display: inline !important;"><strong><span style="text-decoration: underline;">Motorized fire damper </span></strong></p>
<p>Fire damper is a device installed in an air distribution system or an air transfer opening designed to close automatically upon detection of heat interrupting airflow and thereby restricting the passage of fire in the process. Fire dampers are installed in fire rated walls/barriers/partitions (sleeve required) where the HVAC ductwork penetrates ensuring that their integrity is maintained. The location and installation procedure of fire dampers should be in accordance with the widely accepted and recommended standard, <i>NFPA 90A – Standard for the installation of Air-Conditioning. </i><br />
<b>Airmaster <a href="http://airmasteroman.com/product/motorized-fire-damper/">Motorized fire damper </a></b>is developed with the intention of maximizing occupant&#8217;s safety.<br />
<strong style="color: #0076ae;">Construction:</strong><br />
<strong>Frame:</strong> High  quality  galvanized  Iron  Sheet  of 1.6mm thickness.<br />
<strong>Blades:</strong> Single skin roll formed from high quality steel sheet of thickness 16 gauge.<br />
<strong>Actuator: </strong>Fast acting , two position Honeywell actuator<br />
<strong>TRD:</strong> Belimo make TRD, 165<span id="main" style="visibility: visible;"><span id="search" style="visibility: visible;">°</span></span> F temperature rating.<br />
<strong>Jamb Seal: </strong>Stainless Steel<br />
<strong style="color: #0076ae;">Description:</strong></p>
</div>
<ul>
<li>All corners of the frame are fully welded (and painted to prevent rust) to ensure sturdy construction for a rattle free operation.</li>
<li>Designed for parallel blade operation.</li>
<li>AMFD model fire dampers are UL 555 classified &amp; manufactured under Airmaster’s strict quality control procedures.</li>
<li>All actuators are externally mounted with 230VAC as standard and are supplied without auxiliary switch as standard.</li>
<li>Actuator position will be based on Clockwise (CW) closure direction as standard.</li>
<li>TRD’s have an inbuilt RESET switch to reopen the damper.</li>
<li>All AMFD models are factory fitted with 400mm wide &amp; 1.2mm thick steel sleeve as standard.</li>
<li>All dampers and TRD’s are factory tested to ensure smooth operation before dispatch.</li>
<li>Can be used in walls/partitions of less than 3 hours fire resistance rating as per NFPA 90-A in accordance with ANSI/UL555 standards.</li>
</ul>
<p><strong style="color: #0076ae;">Maximum Approved Sizes:</strong></p>
<ul>
<li>Multiple section : 70” x 70” (vertical installation only)</li>
<li>Single section : 35” x 35” (vertical installation only)</li>
</ul>
<p>The post <a href="https://airmasteroman.com/product/motorized-fire-damper/">Motorized Fire Damper</a> appeared first on <a href="https://airmasteroman.com">Airmaster Oman</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Motorized Fire &#038; Smoke Damper</title>
		<link>https://airmasteroman.com/product/motorized-fire-smoke-damper/</link>
		
		<dc:creator><![CDATA[ammism]]></dc:creator>
		<pubDate>Thu, 25 Feb 2016 21:47:01 +0000</pubDate>
				<guid isPermaLink="false">http://localhost/airmaster1/product/motorized-fire-smoke-damper/</guid>

					<description><![CDATA[<h4>Construction:</h4>
<p>Frame: High quality galvanized Iron Sheet of 1.6mm thickness.<br />
Blades: Single skin roll formed from high quality steel sheet of thickness 16 gauge.<br />
Actuator: Fast acting , two position Honeywell actuator<br />
TRD: Belimo make TRD, 165° F temperature rating.<br />
Gasket: UL Listed</p>
<p>The post <a href="https://airmasteroman.com/product/motorized-fire-smoke-damper/">Motorized Fire &#038; Smoke Damper</a> appeared first on <a href="https://airmasteroman.com">Airmaster Oman</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div style="font-family: Verdana,Arial,Helvetica,sans-serif;"><strong><span style="text-decoration: underline;">Motorized fire &amp; smoke damper or Combination fire and smoke damper</span></strong><br />
Fire damper is a device installed in an air distribution system or an air transfer opening designed to close automatically upon detection of heat interrupting airflow and thereby restricting the passage of fire in the process. Fire dampers are installed in fire rated walls/barriers/partitions (sleeve required) where the HVAC ductwork penetrates ensuring that their integrity is maintained. The location and installation procedure of fire dampers should be in accordance with the widely accepted and recommended standard, <i>NFPA 90A – Standard for the installation of Air-Conditioning. </i><br />
<b>Airmaster <a href="http://airmasteroman.com/product/motorized-fire-smoke-damper">Motorized fire and smoke damper</a> / Combination fire and smoke damper</b> is developed with the intention of maximizing occupant&#8217;s safety.<br />
<strong style="color: #0076ae;">Construction:</strong><br />
<strong>Frame:</strong> High  quality  galvanized  Iron  Sheet  of 1.6mm thickness.<br />
<strong>Blades:</strong> Single skin roll formed from high quality steel sheet of thickness 16 gauge.<br />
<strong>Actuator: </strong>Fast acting , two position Honeywell actuator<br />
<strong>TRD:</strong> Belimo make TRD, 165<span id="main" style="visibility: visible;"><span id="search" style="visibility: visible;">°</span></span> F temperature rating.<br />
<strong>Gasket: </strong>UL  Listed<br />
<strong style="color: #0076ae;">Description:</strong></div>
<ul>
<li>All corners of the frame are fully welded (and painted to prevent rust) to ensure sturdy construction for a rattle free operation.</li>
<li>Designed for parallel blade operation.</li>
<li>AMFSD series combination Fire/Smoke dampers are UL 555/555S classified, manufactured under Airmaster’s strict quality control procedures.</li>
<li>AMFSD Dampers are available with Class II leakage rating at 2000fpm (10.2m/s) / 4”w.g (1000pa). Suitable for most of the commercial smoke management applications in both static and dynamic systems.</li>
<li>All actuators are externally mounted with 230VAC as standard.</li>
<li>Actuators are supplied without auxiliary switch as standard.</li>
<li>Actuator position will be based on Clockwise (CW) closure direction as standard.</li>
<li>TRD’s have an inbuilt RESET switch to reopen the damper.</li>
<li>All AMFSD models are factory fitted with 400mm wide &amp; 1.2mm thick steel sleeve as standard</li>
<li>All dampers and TRD’s are factory tested to ensure smooth operation before dispatch.</li>
<li>Actuators have to be configured with control panel or BMS system for smoke control applications before commissioning.</li>
<li>Can be used in walls/partitions of less than 3 hours fire resistance rating as per NFPA 90-A in accordance with ANSI/UL555 standards.</li>
</ul>
<p><strong style="color: #0076ae;">Maximum Approved Sizes:</strong></p>
<ul>
<li>Multiple section : 70” x 70” (vertical installation only)</li>
<li>Single section : 35” x 35” (vertical installation only)</li>
</ul>
<p>The post <a href="https://airmasteroman.com/product/motorized-fire-smoke-damper/">Motorized Fire &#038; Smoke Damper</a> appeared first on <a href="https://airmasteroman.com">Airmaster Oman</a>.</p>